• Old compressor unmount and recycling according EPA standards;
• Replacing freon filter drier;
• New compressor installation;
• Nitrogen test performing to to exclude the possibility of refrigerant leaks;
• Vacuuming sealed system to 500 micron vacuum deep;
• Charging sealed system with new refrigerant;
• System test.
After the replacement the refrigerator was as good as new.